<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>17006</ErrorNumber>
<ErrorFamily>Exposure Head</ErrorFamily>
<ErrorMessage>
HEAD: Datalink timed out waiting for break
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Thermal</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The firmware cannot detect the head. Check exposure head cables and power supplies.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Reboot the platesetter.  Even if this error does not happen again, please report it to Creo Service as the
Platesetter may need servicing.
</text></DescriptionText>
</OperatorAction>
<Cause>
Faulty cable or poor cable connection
</Cause>
<Cause>
Failed exposure head power supply
</Cause>
<Cause>
Faulty exposure head
</Cause>